3-20 Section 3: Installation
Moseley SL9003Q 602-12016 Revision G
data rate. By pressing ENTER while viewing the screen, the error count will reset to
zero. This is useful while making antenna adjustments, as erroneous errors can be
eliminated from the display for ease of use.
After peak alignment is achieved, tighten the bolts to hold the antenna securely. Double-
check the RSL and BER STATUS indications. Link alignment is complete.